Contacteur 460A-AC3/3P+(1NO+1NC) AF460-30-11 (250-500VAC/DC-50/60Hz)

(0 Commentaires)
Marque
ABB

Produit en interne


Prix
124.950,00 DA /Pc
Quantité
(2000 disponible)
Prix ​​total
Partager

Avis et notes

0 sur 5.0
(0 Commentaires)
Il n'y a pas encore d'avis sur ce produit.

Technique

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Tension:
    Circuit principal 1000 V
  • Fréquence assignée (f):
    Circuit principal 50 / 60 Hz
  • Courant thermique conventionnel à l’air libre (Ith):
    acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A
  • Courant assignée d’emploi AC-1 (Ie):
    (1000 V) 40 °C 700 A
    (1000 V) 55 °C 600 A
    (1000 V) 60 °C 600 A
    (1000 V) 70 °C 480 A
    (690 V) 40 °C 700 A
    (690 V) 55 °C 600 A
    (690 V) 70 °C 480 A
  • Courant assignée d’emploi AC-3 (Ie):
    (415 V) 55 °C 460 A
    (440 V) 55 °C 460 A
    (500 V) 55 °C 460 A
    (690 V) 55 °C 400 A
    (1000 V) 55 °C 200 A
    (380 / 400 V) 55 °C 460 A
    (220 / 230 / 240 V) 55 °C 460
  • Puissance assignée d’emploi AC-3 (Pe):
    (415 V) 250 kW
    (440 V) 250 kW
    (500 V) 315 kW
    (690 V) 355 kW
    (1000 V) 280 kW
    (380 / 400 V) 250 kW
    (220 / 230 / 240 V) 132 kW
  • Pouvoir assigné de coupure AC-3:
    8 x Ie AC-3
  • Pouvoir assigné de fermeture AC-3:
    10 x Ie AC-3
  • Dispositif de protection contre les courts-circuits:
    gG Type Fuses 800 A
  • Courant assigné de courte durée admissible (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
  • Maximum Electrical Switching Frequency:
    (AC-1) 300 cycles per hour
    (AC-2 / AC-4) 60 cycles per hour
    (AC-3) 300 cycles per hour
  • Courant assignée d’emploi DC-1 (Ie):
    (110 V) 1-Pole, 40 °C 700 A
    (110 V) 2 Poles in Series, 40 °C 700 A
    (220 V) 3 Poles in Series, 40 °C 700 A
    (600 V) 3 Poles in Series, 40 °C 700 A
  • Courant assignée d’emploi DC-3 (Ie):
    (110 V) 1-Pole, 40 °C 700 A
    (110 V) 2 Poles in Series, 40 °C 700 A
    (220 V) 3 Poles in Series, 40 °C 700 A
    (600 V) 3 Poles in Series, 40 °C 700 A
  • Courant assignée d’emploi DC-5 (Ie):
    (110 V) 1-Pole, 40 °C 700 A
    (110 V) 2 Poles in Series, 40 °C 700 A
    (220 V) 3 Poles in Series, 40 °C 700 A
    (600 V) 3 Poles in Series, 40 °C 700 A
  • Tension assignée d’isolement (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Tension assignée de tenue aux chocs (Uimp):
    Circuit principal 8 kV
  • Durabilite mecanique:
    5 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Plage d'utilisation de la bobine selon:
    (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc):
    50 Hz 250 ... 500 V
    60 Hz 250 ... 500 V
    DC Operation 250 ... 500 V
  • Coil Consumption:
    Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
    Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 950 V·A
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 950 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 885 V·A
  • Durée de fonctionnement nominale:
    Entre la mise hors tension de la bobine et la fermeture du contact NC (normally closed) 45 ... 55 ms
    Entre la mise hors tension de la bobine et l'ouverture du contact NO (normally open) 48 ... 58 ms
    Entre la mise sous tension de la bobine et l'ouverture du contact NC 45 ... 115 ms
    Entre la mise sous tension de la bobine et la fermeture du contact NO 50 ... 120 ms
  • Connecting Capacity Main Circuit:
    Bar 47 mm²
    Rigid Al-Cable 2x240 mm²
    Rigid Cu-Cable 240 mm²
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
    Flexible 2x0.75 ... 2.5 mm²
    Solid 2 x 1 ... 4 mm²
    Stranded 2 x 1 .... 4 mm²
  • Indice de protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Type de borne:
    Main Circuit: Bars

Technique UL/CSA

  • NEMA Size:
    6
  • Horsepower Rating NEMA:
    (200 V AC) Three Phase 150 Hp
    (230 V AC) Three Phase 200 Hp
    (460 V AC) Three Phase 400 Hp
    (575 V AC) Three Phase 400 Hp
  • Maximum Operating Voltage UL/CSA:
    Circuit principal 1000 V
  • General Use Rating UL/CSA:
    (600 V AC) 650 A
  • Puissance nominale UL/CSA:
    (200 V AC) Three Phase 150 hp
    (208 V AC) Three Phase 150 hp
    (220 ... 240 V AC) Three Phase 200 hp
    (440 ... 480 V AC) Three Phase 400 hp
    (550 ... 600 V AC) Three Phase 500 hp